Campbell Scientific CSIM11 – Water pH Sensor
The Campbell Scientific CSIM11 is a submersible pH sensor for natural, surface, and process-water monitoring. It measures the full 0 to 14 pH range and includes an internal amplifier for stable signals and reduced electrical interference.
Campbell Scientific CSIM11 – Water pH Sensor
The Campbell Scientific CSIM11 is a submersible analog sensor for measuring pH in natural, surface, and process water. It covers the complete 0 to 14 pH range and can be submerged or installed in tanks, open channels, and non-pressurised pipelines.
The sensor uses a glass pH electrode and a porous PTFE liquid junction that is less susceptible to clogging than conventional reference junctions. Its plunger-style electrode allows installation at different angles.
Key Benefits
- full 0 to 14 pH measurement range;
- designed for natural and surface-water applications;
- internal amplifier for reduced signal interference;
- titanium ground rod for reducing ground-loop errors;
- porous PTFE junction with reduced susceptibility to clogging;
- does not require power from the datalogger;
- fast response time;
- compatible with Campbell Scientific dataloggers;
- programmable using Short Cut and CRBasic.
Temperature Compensation
The CSIM11 requires one differential analog input. It does not contain a temperature sensor or automatically compensate the pH reading for changes in water temperature.
For accurate measurements, install a separate submersible temperature sensor near the pH electrode. Temperature compensation can be performed in the datalogger program or during subsequent data processing.
Installation and Maintenance
The CSIM11 can be submerged or installed in tanks, open channels, and water systems operating at pressures of up to 30 psig.
The sensor should be checked and calibrated using suitable pH buffer solutions. The glass electrode and reference junction require periodic cleaning. The expected service life of the glass electrode is approximately six months to two years, depending on water conditions and maintenance.
View the other dataloggers for automated monitoring available from Solitech.
| Модел | Campbell Scientific CSIM11 |
| Тип устройство | Потопяем аналогов pH сензор |
| Измервателен диапазон | 0 до 14 pH |
| Нулев потенциал | 7.0 pH ±0.2 pH |
| Изходен сигнал | ±59 mV за pH единица |
| Точност | ±0.1% от пълния диапазон |
| Време за реакция | 95% от показанието за 10 s |
| Дрейф | Под 2 mV на седмица |
| Работна температура | От 0°C до +80°C |
| Допустимо налягане | От 0 до 30 psig |
| Необходим вход на дейталогера | 1 диференциален аналогов вход |
| Температурна компенсация | Чрез отделен температурен сензор |
| Референтна клетка | Единична KCl/AgCl връзка |
| Импеданс | Под 1 MΩ при 25°C |
| Материали в контакт с течността | ABS, PTFE, Viton, стъкло и титан |
| Материал на кабелната обвивка | Полиуретан |
| Захранване на усилвателя | Вътрешни литиеви батерии |
| Диаметър | 3.0 cm |
| Дължина | 17.8 cm |
| Тегло | 0.5 kg с кабел 4.57 m |
Campbell Scientific CSIM11 – Water pH Sensor
The Campbell Scientific CSIM11 is a submersible analog sensor for measuring pH in natural, surface, and process water. It covers the complete 0 to 14 pH range and can be submerged or installed in tanks, open channels, and non-pressurised pipelines.
The sensor uses a glass pH electrode and a porous PTFE liquid junction that is less susceptible to clogging than conventional reference junctions. Its plunger-style electrode allows installation at different angles.
Key Benefits
- full 0 to 14 pH measurement range;
- designed for natural and surface-water applications;
- internal amplifier for reduced signal interference;
- titanium ground rod for reducing ground-loop errors;
- porous PTFE junction with reduced susceptibility to clogging;
- does not require power from the datalogger;
- fast response time;
- compatible with Campbell Scientific dataloggers;
- programmable using Short Cut and CRBasic.
Temperature Compensation
The CSIM11 requires one differential analog input. It does not contain a temperature sensor or automatically compensate the pH reading for changes in water temperature.
For accurate measurements, install a separate submersible temperature sensor near the pH electrode. Temperature compensation can be performed in the datalogger program or during subsequent data processing.
Installation and Maintenance
The CSIM11 can be submerged or installed in tanks, open channels, and water systems operating at pressures of up to 30 psig.
The sensor should be checked and calibrated using suitable pH buffer solutions. The glass electrode and reference junction require periodic cleaning. The expected service life of the glass electrode is approximately six months to two years, depending on water conditions and maintenance.
View the other dataloggers for automated monitoring available from Solitech.
| Model | Campbell Scientific CSIM11 |
| Device type | Submersible analog pH sensor |
| Measurement range | 0 to 14 pH |
| Zero potential | 7.0 pH ±0.2 pH |
| Sodium error | Less than 0.05 pH in 0.1 molar Na+ solution at 12.8 pH |
| Output signal | ±59 mV per pH unit |
| Accuracy | ±0.1% over the full measurement range |
| Response time | 95% of the reading within 10 seconds |
| Drift | Less than 2 mV per week |
| Operating temperature range | 0°C to +80°C |
| Pressure range | 0 to 30 psig |
| Required datalogger input | One differential analog input |
| Temperature compensation | Requires an external water-temperature measurement |
| Impedance | Less than 1 MΩ at 25°C |
| Reference cell | Single-junction KCl/AgCl |
| Liquid junction | Porous polytetrafluoroethylene (PTFE) |
| Body material | ABS |
| Wetted materials | ABS, PTFE, Viton, glass, and titanium |
| Cable-jacket material | Polyurethane |
| Amplifier power | Two internal 3 VDC lithium batteries |
| Internal-battery lifetime | Approximately 5 years or the expected life of the probe |
| External power requirement | No power required from the datalogger |
| Sensor diameter | 3.0 cm |
| Sensor length | 17.8 cm |
| Weight | 0.5 kg with a 4.57 m cable |
| Typical probe life | Approximately 6 months to 2 years, depending on water conditions and maintenance |
| Standard warranty | 6 months |
Related products
-
Campbell Scientific ClariVue 20 – Turbidity Sensor
Accurate turbidity and suspended-particle measurement in freshwater, marine, and industrial-water environments. -
Campbell Scientific CS547A – Water Conductivity and Temperature Sensor
Reliable electrical-conductivity and temperature measurement for long-term freshwater-quality monitoring.