Campbell Scientific CS547A – Water Conductivity and Temperature Sensor
The Campbell Scientific CS547A is a submersible sensor for measuring the electrical conductivity and temperature of fresh water. Its corrosion-resistant epoxy housing, stainless-steel electrodes, and 305 m depth rating make it suitable for rivers, wells, boreholes, and water-quality monitoring systems. An A547 interface is required and must be ordered separately.
Campbell Scientific CS547A – Water Conductivity and Temperature Sensor
The Campbell Scientific CS547A is a submersible analog sensor for measuring the electrical conductivity and temperature of fresh water. It is suitable for long-term monitoring in rivers, streams, wells, boreholes, reservoirs, groundwater systems, and other freshwater environments.
Electrical conductivity is measured using three cylindrical passivated stainless-steel electrodes mounted in a rugged epoxy housing. Water temperature is measured using an integrated thermistor. Conductivity data may also be used to estimate total dissolved solids by applying an appropriate empirical conversion factor.
Important: the CS547A requires a Campbell Scientific A547 interface for connection to a data logger. The interface contains the blocking capacitors and bridge-completion resistors required for the measurement. The A547 is ordered separately and is normally installed inside the data-logger enclosure.
Key Benefits
- simultaneous water electrical-conductivity and temperature measurement;
- approximate conductivity range from 0.005 to 7 mS/cm;
- temperature range from 0°C to +50°C;
- maximum deployment depth of 305 m;
- durable and easy-to-clean epoxy housing;
- three passivated 316 stainless-steel electrodes;
- reduced ground-loop and electrochemical-corrosion problems;
- individually calibrated cell constant;
- integrated thermistor for temperature measurement and compensation;
- cable lengths available up to 305 m;
- compatible with Campbell Scientific data loggers;
- compatible with AM16/32B multiplexers for multiple-sensor systems;
- optional weighted cable for stand-alone submersion.
Measurement Principle
The CS547A measures the electrical resistance of water passing through the opening in the probe body. Its centre electrode is excited using positive and negative voltage, and the resulting analog signal is measured by the data logger.
The electrodes are AC-coupled and bipolar excitation is applied. This reduces electrochemical reactions, minimises corrosion, and extends the service life of the probe.
Each sensor is supplied with an individually calibrated cell constant. This value is printed on a label near the cable termination and must be entered in the data-logger program.
Temperature Measurement and Compensation
The integrated thermistor measures water temperature from 0°C to +50°C. The temperature measurement can be used to correct conductivity measurements to a selected reference temperature.
The data-logger program should compensate the measurement for cable resistance, ionisation effects, and water temperature.
A547 Interface and Data-Logger Connection
The CS547A does not use SDI-12, Modbus, or RS-485 communication. It provides an analog signal and requires an A547 interface.
The measurement requires one differential analog input, one single-ended analog input, and two separate voltage-excitation channels. One A547 interface is normally required for each directly connected probe.
Up to 16 CS547A sensors can be connected through an AM16/32B multiplexer and one A547 interface. In this configuration, the multiplexer must be dedicated to the CS547A sensors and cannot be shared with other sensor types.
Installation
The probe should be positioned so that water can flow freely through its central measurement opening. In streams and flowing water, the probe should be aligned parallel to the direction of flow.
The sensor has slight positive buoyancy and should be secured to a fixed mounting structure or installed using the optional weighted-cable configuration. A strain-relief sleeve is recommended for cable lengths exceeding 30 m.
Limitations
- designed for freshwater applications and not recommended for seawater;
- solutions below pH 3 or above pH 9 may damage the stainless-steel electrodes;
- ice forming inside the probe cavity can damage the sensor;
- rapid temperature changes should be avoided;
- long cables in electrically noisy environments may affect measurement quality.
Applications
- freshwater-quality monitoring;
- river, stream, lake, and reservoir monitoring;
- groundwater and well monitoring;
- hydrological and environmental stations;
- tracking dissolved salts and minerals;
- monitoring pollutants in aquifers;
- drainage and industrial-water monitoring;
- watershed and water-movement studies;
- automated Campbell Scientific monitoring systems.
Compatibility
The CS547A is compatible with current Campbell Scientific data loggers, including the CR310, CR350, CR6, and CR1000Xe. The data logger must provide the required analog inputs and separate voltage-excitation channels.
Measurement programs can be created using Short Cut or CRBasic. Campbell Scientific also provides example programs for measurement, calibration, and conductivity correction.
| Модел | Campbell Scientific CS547A |
| Тип устройство | Потопяем сензор за електропроводимост и температура на вода |
| Предназначение | Измерване в сладка вода |
| Измервани параметри | Електропроводимост и температура |
| Изход | Аналогов; изисква интерфейс A547 |
| Максимален аналогов сигнал | До 2500 mVDC |
| Диапазон на електропроводимостта | Приблизително 0.005 до 7.0 mS/cm |
| Точност на електропроводимостта | ±5% от показанието при 0.44 до 7.0 mS/cm |
| Точност при ниска електропроводимост | ±10% от показанието при 0.005 до 0.44 mS/cm |
| Грешка на мостовото измерване | Под 1% |
| Температурен сензор | Термистор Betatherm 100K6A1 |
| Температурен диапазон | 0°C до +50°C |
| Типична грешка при линеаризация | Под 0.1°C в диапазона от 0°C до +48°C |
| Типична взаимозаменяемост на термистора | Под 0.2°C в диапазона от 0°C до +50°C |
| Клетъчна константа | Индивидуално калибрирана и означена върху кабела |
| Електроди | Три пасивирани електрода от неръждаема стомана 316 |
| Материали в контакт с водата | Епоксиден корпус, неръждаема стомана 316 и полиуретанов кабел |
| Допустим диапазон на pH | Разтвори под pH 3 или над pH 9 могат да повредят електродите |
| Максимална дълбочина | 305 m |
| Максимална дължина на кабела | 305 m; дължината трябва да бъде избрана при поръчката |
| Минимален вътрешен диаметър на тръба | 28 mm |
| Необходими входове на дейталогера | 1 диференциален и 1 еднополюсен аналогов вход |
| Необходими възбуждащи канали | 2 отделни канала; единият трябва да поддържа двуполярно възбуждане |
| Необходим интерфейс | Campbell Scientific A547, поръчва се отделно |
| Съвместим мултиплексор | AM16/32B; до 16 сензора CS547A |
| Размери | 8.9 × 2.54 × 1.9 cm |
| Тегло на сензора | 45 g |
| Тегло с кабел 1.22 m | 120 g |
Campbell Scientific CS547A – Water Conductivity and Temperature Sensor
The Campbell Scientific CS547A is a submersible analog sensor for measuring the electrical conductivity and temperature of fresh water. It is suitable for long-term monitoring in rivers, streams, wells, boreholes, reservoirs, groundwater systems, and other freshwater environments.
Electrical conductivity is measured using three cylindrical passivated stainless-steel electrodes mounted in a rugged epoxy housing. Water temperature is measured using an integrated thermistor. Conductivity data may also be used to estimate total dissolved solids by applying an appropriate empirical conversion factor.
Important: the CS547A requires a Campbell Scientific A547 interface for connection to a data logger. The interface contains the blocking capacitors and bridge-completion resistors required for the measurement. The A547 is ordered separately and is normally installed inside the data-logger enclosure.
Key Benefits
- simultaneous water electrical-conductivity and temperature measurement;
- approximate conductivity range from 0.005 to 7 mS/cm;
- temperature range from 0°C to +50°C;
- maximum deployment depth of 305 m;
- durable and easy-to-clean epoxy housing;
- three passivated 316 stainless-steel electrodes;
- reduced ground-loop and electrochemical-corrosion problems;
- individually calibrated cell constant;
- integrated thermistor for temperature measurement and compensation;
- cable lengths available up to 305 m;
- compatible with Campbell Scientific data loggers;
- compatible with AM16/32B multiplexers for multiple-sensor systems;
- optional weighted cable for stand-alone submersion.
Measurement Principle
The CS547A measures the electrical resistance of water passing through the opening in the probe body. Its centre electrode is excited using positive and negative voltage, and the resulting analog signal is measured by the data logger.
The electrodes are AC-coupled and bipolar excitation is applied. This reduces electrochemical reactions, minimises corrosion, and extends the service life of the probe.
Each sensor is supplied with an individually calibrated cell constant. This value is printed on a label near the cable termination and must be entered in the data-logger program.
Temperature Measurement and Compensation
The integrated thermistor measures water temperature from 0°C to +50°C. The temperature measurement can be used to correct conductivity measurements to a selected reference temperature.
The data-logger program should compensate the measurement for cable resistance, ionisation effects, and water temperature.
A547 Interface and Data-Logger Connection
The CS547A does not use SDI-12, Modbus, or RS-485 communication. It provides an analog signal and requires an A547 interface.
The measurement requires one differential analog input, one single-ended analog input, and two separate voltage-excitation channels. One A547 interface is normally required for each directly connected probe.
Up to 16 CS547A sensors can be connected through an AM16/32B multiplexer and one A547 interface. In this configuration, the multiplexer must be dedicated to the CS547A sensors and cannot be shared with other sensor types.
Installation
The probe should be positioned so that water can flow freely through its central measurement opening. In streams and flowing water, the probe should be aligned parallel to the direction of flow.
The sensor has slight positive buoyancy and should be secured to a fixed mounting structure or installed using the optional weighted-cable configuration. A strain-relief sleeve is recommended for cable lengths exceeding 30 m.
Limitations
- designed for freshwater applications and not recommended for seawater;
- solutions below pH 3 or above pH 9 may damage the stainless-steel electrodes;
- ice forming inside the probe cavity can damage the sensor;
- rapid temperature changes should be avoided;
- long cables in electrically noisy environments may affect measurement quality.
Applications
- freshwater-quality monitoring;
- river, stream, lake, and reservoir monitoring;
- groundwater and well monitoring;
- hydrological and environmental stations;
- tracking dissolved salts and minerals;
- monitoring pollutants in aquifers;
- drainage and industrial-water monitoring;
- watershed and water-movement studies;
- automated Campbell Scientific monitoring systems.
Compatibility
The CS547A is compatible with current Campbell Scientific data loggers, including the CR310, CR350, CR6, and CR1000Xe. The data logger must provide the required analog inputs and separate voltage-excitation channels.
Measurement programs can be created using Short Cut or CRBasic. Campbell Scientific also provides example programs for measurement, calibration, and conductivity correction.
| Model | Campbell Scientific CS547A |
| Device type | Submersible water conductivity and temperature sensor |
| Application | Freshwater measurement |
| Measured parameters | Electrical conductivity and temperature |
| Output | Analog; requires an A547 interface |
| Maximum analog signal | Up to 2500 mVDC |
| Conductivity range | Approximately 0.005 to 7.0 mS/cm |
| Conductivity accuracy | ±5% of reading from 0.44 to 7.0 mS/cm |
| Low-range conductivity accuracy | ±10% of reading from 0.005 to 0.44 mS/cm |
| Bridge measurement error | Less than 1% |
| Temperature sensor | Betatherm 100K6A1 thermistor |
| Temperature range | 0°C to +50°C |
| Typical polynomial linearisation error | Less than 0.1°C from 0°C to +48°C |
| Typical thermistor interchangeability | Less than 0.2°C from 0°C to +50°C |
| Cell constant | Individually calibrated and marked on the cable |
| Electrodes | Three passivated 316 stainless-steel electrodes |
| Wetted materials | Epoxy housing, 316 stainless steel, and polyurethane cable |
| Permitted pH range | Solutions below pH 3 or above pH 9 may damage the electrodes |
| Maximum deployment depth | 305 m |
| Maximum cable length | 305 m; required length must be selected when ordering |
| Minimum pipe internal diameter | 28 mm |
| Required data-logger inputs | 1 differential and 1 single-ended analog input |
| Required excitation channels | 2 separate channels; one must support bipolar excitation |
| Required interface | Campbell Scientific A547, ordered separately |
| Compatible multiplexer | AM16/32B; up to 16 CS547A sensors |
| Dimensions | 8.9 × 2.54 × 1.9 cm |
| Sensor weight | 45 g |
| Weight with 1.22 m cable | 120 g |
Related products
-
Campbell Scientific CSIM11 – Water pH Sensor
Reliable pH measurement in natural water, tanks, open channels, and non-pressurised water systems. -
Campbell Scientific ClariVue 20 – Turbidity Sensor
Accurate turbidity and suspended-particle measurement in freshwater, marine, and industrial-water environments.