Campbell Scientific CR6

The CR6 Measurement and Control Datalogger is a powerful core component for your data-acquisition system. The CR6 datalogger provides fast communication, low power requirements, built-in USB, compact size, and high analog input accuracy and resolution. It uses universal (U) terminals to allow a connection to virtually any sensor—analog, digital, or smart. This multipurpose datalogger is also capable of doing static vibrating-wire measurements.

The CR6 can include integrated radio options:

  • CR6-RF407: 900 MHz (United States and Canada)
  • CR6-RF412: 920 MHz (Australia and New Zealand)
  • CR6-RF422: 868 MHz (Europe)
  • CR6-RF451: 900 MHz, 1 W (United States, Canada, and Australia)
  • CR6-WIFI: 2.4 GHz

For more information go to: https://www.campbellsci.com/dataloggers



Benefits and Features

  • Operational in extreme environments with a standard operating range of -40° to +70°C and an extended operating range of -55° to +85°C
  • Connects directly to a computer’s USB port
  • U terminals configurable to what you want them to be: analog or digital, input or output
  • Supports static vibrating-wire measurements using our patented VSPECT™ spectral analysis technology
  • Differentiates even slight changes in data values with high-resolution measurements (to 0.05 µV, 24 bit Adc)
  • Contains an onboard CPI port for hosting Campbell sensors and distributed modules (CDMs)
  • Directly connects to Ethernet with 10/100 Ethernet RJ-45 or Ethernet over USB (virtual Ethernet)
  • Includes a microSD card drive for extended memory requirements
  • Provides simple serial sensor integration and measurement with SDI-12, RS-232, and/or RS-485
  • Supports full PakBus® networking
  • Includes an embedded web page for direct connection via web browser
Модел CR6
CPU 32 бита с хардуерен FPU, работещ на 100 MHz
Външна памет 4 MB SRAM за хранилище за данни, 1 MB флаш за програми, 6 MB за операционна система
Micro SD Drive за допълнителна памет до 16 GB
Точност на часовника ±3 минути за година, по избор GPS корекция до 10 μs
USB micro B за директна връзка с компютър 2.0 пълна скорост, 12 Mbps
Тегло 0.42 kg (0.92 lb)
Дименсии 20.3 x 10.2 x 6.1 cm (8.0 x 4.0 x 2.4 in)
Най-добра аналогова точност ±(0.04% от четенията + 2 µV), при от 0° до 40°C
Най-ефективна резолюция 50 nV (±200 mV диапазон, диференциални измервания, обратен вход, 5 Hz fN1)
CPI интерфейс Campbell Distributed модули (CDM)
Сертификати CE одобрен
Комуникационни интерфейси 10/100 Ethernet RJ-45 за LAN връзка
CS I/Oпорт за връзка с модеми и дисплеи на Campbell Scientific 
Захранващ блок(-BAT+) За регулиран 12 V захранващ порт или презареждаща се 12 V VRLA за UPS режим, 2.5 A @ 20°C
Зареждащ захранващ блок (-CHG+) За от 16 до 32 V от dc конвертор за мощност или 12 или 24 V соларен панелl , 1.2 A @ 20°C

 

Benefits and Features

  • Operational in extreme environments with a standard operating range of -40° to +70°C and an extended operating range of -55° to +85°C
  • Connects directly to a computer’s USB port
  • U terminals configurable to what you want them to be: analog or digital, input or output
  • Supports static vibrating-wire measurements using our patented VSPECT™ spectral analysis technology
  • Differentiates even slight changes in data values with high-resolution measurements (to 0.05 µV, 24 bit Adc)
  • Contains an onboard CPI port for hosting Campbell sensors and distributed modules (CDMs)
  • Directly connects to Ethernet with 10/100 Ethernet RJ-45 or Ethernet over USB (virtual Ethernet)
  • Includes a microSD card drive for extended memory requirements
  • Provides simple serial sensor integration and measurement with SDI-12, RS-232, and/or RS-485
  • Supports full PakBus® networking
  • Includes an embedded web page for direct connection via web browser
ModelCR6
Operating Temperature Range

-40° to +70°C (standard)

-55° to +85°C (extended)

Universal Inputs12 individually configured inputs for analog or digital functions
Pulse Counters16 (C1 to P4 and U1 to U12)
Communications Ports

Ethernet

USB

CS I/O

RS-232

CPI

RS-485

SDI-12

Data Storage PortsmicroSD
Switched 12 Volt2 terminals
Digital I/O16 terminals (C1 to C4, U1 to U12) configurable for digital input and output. Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.
Input Limits±5 V
Analog Voltage Accuracy

Accuracy specifications do not include sensor or measurement noise.

±(0.04% of measurement + offset) at 0° to 40°C

±(0.06% of measurement + offset) at -40° to +70°C

±(0.08% of measurement + offset) at -55° to +85°C (extended temperature range)

ADC24-bit
Power Requirements

16 to 32 Vdc for charger input (CHG)

10 to 18 Vdc for battery input (BAT)

Real-Time Clock Accuracy±3 min. per year (optional GPS correction to 10 µs)
Internet ProtocolsEthernet, PPP, CS I/O IP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS, DNS, DHCP, SLAAC, SNMPv3, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS
Communication ProtocolsPakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others
Warranty3 years (against defects in materials and workmanship)
Battery-backed SRAM for CPU Usage & Final Storage4 MB
Data Storage4 MB SRAM + 72 MB flash (Storage expansion of up to 8 GB with removable microSD flash memory card.)
Idle Current Drain, Average

Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.

< 1 mA

Active Current Drain, Average

Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.

3 mA (1 Hz scan)

67 mA (20 Hz scan)

Static Vibrating-Wire MeasurementsSupported
Dimensions20.3 x 10.1 x 5.6 cm (8.0 x 4.0 x 2.2 in.)
Additional clearance required for cables and leads.
Weight0.42 to 0.52 kg (0.92 to 1.15 lb) depending on communication option selected