Campbell Scientific CR310

The Campbell Scientific CR310 is a multipurpose measurement, data acquisition, and control datalogger designed for small and medium-sized applications requiring reliable long-term operation, remote access, and low power consumption.



Campbell Scientific CR310 – Compact Datalogger with Ethernet

The CR310 can measure a wide range of hydrological, meteorological, environmental, geotechnical, and industrial sensors. It processes and stores measurements, performs automated control functions, and makes data available through a variety of communication networks and protocols.

The main differences between the CR310 and CR300 are the integrated 10/100 Ethernet RJ45 port and the removable terminal connectors. The Ethernet interface allows direct connection to a local network, industrial router, or internet gateway without requiring a separate Ethernet communication module.

Key Benefits

  • integrated 10/100 Ethernet RJ45 port;
  • removable terminal connectors for easier wiring and maintenance;
  • USB Micro-B port for initial setup and local communication;
  • RS-232 interface for serial sensors and communication devices;
  • six analog inputs configurable as six single-ended or three differential channels;
  • 24-bit analog-to-digital converter;
  • support for SDI-12 sensors and pulse or frequency signals;
  • 0–20 mA and 4–20 mA measurements through the SE1 and SE2 inputs;
  • integrated charge regulator for a 12 V battery and solar panel;
  • integrated surge, electrostatic discharge, and power-input protection;
  • programmable using CRBasic and configurable using Short Cut;
  • suitable for autonomous and solar-powered monitoring stations.

Measurement Inputs and Control

The CR310 provides six multipurpose analog inputs that can be configured as six single-ended or three differential channels. The inputs support voltage measurements, thermocouples, thermistors, RTDs, current signals, and resistive bridge measurements.

The datalogger also provides pulse inputs, configurable digital inputs and outputs, two programmable voltage excitation terminals, and a switched 12 V output for powering sensors and communication devices.

Communication and Remote Access

The integrated Ethernet port allows the CR310 to connect directly to a local network or the internet. Supported services and protocols include HTTP and HTTPS, FTP and FTPS, email, TCP, UDP, TLS, Modbus, DNP3, PakBus, and SDI-12.

For remote installations, the CR310 can be combined with cellular or satellite communication peripherals. Versions with integrated Wi-Fi, radio, or cellular communication are also available.

Versions for Europe

  • CR310 – standard version with Ethernet, USB, and RS-232;
  • CR310-WIFI – version with integrated 2.4 GHz Wi-Fi communication;
  • CR310-RF422 – version with integrated 868 MHz radio for the European Union;
  • CR310-CELL215 – version with integrated 4G LTE CAT-1 communication for Europe, the Middle East, and Africa.
    See more for CELL215.

Applications

The Campbell Scientific CR310 is suitable for:

  • geotechnical and structural monitoring;
  • monitoring landslides, dams, bridges, and infrastructure facilities;
  • meteorological and agrometeorological stations;
  • water-resource and hydrological monitoring;
  • environmental and soil monitoring;
  • agricultural measurement systems;
  • energy and photovoltaic installations;
  • industrial measurement and automated control.

Compatibility and Programming

The CR310 is programmed using CRBasic and can be configured with Campbell Scientific Short Cut, Device Configuration Utility, PC400, or LoggerNet. It supports analog, pulse, RS-232, SDI-12, Modbus, and other serial sensors.

The CR310 does not directly support RS-485 sensors and is not compatible with SDM or CDM peripheral devices. A suitable converter is required for RS-485 communication.

Модел Campbell Scientific CR310
Тип устройство Дейталогер за измерване и автоматизирано управление
Процесор ARM Cortex-M4, 144 MHz
Памет за програми 80 MB serial flash
Памет за съхранение на данни 30 MB serial flash
Максимална честота на сканиране 10 Hz
Аналогови входове 6 еднополюсни или 3 диференциални входа
Аналогово-цифров преобразувател 24-bit ADC
Диапазон на аналоговите входове от –100 до +2500 mV и диапазон ±34 mV
Токови сигнали 0–20 mA или 4–20 mA чрез SE1 и SE2
Точност на аналоговото измерване ±(0.04% от измерването + offset) при 0°C до +40°C
Импулсни броячи 8
Цифрови входове и изходи 7 програмируеми терминала
Терминали за възбуждащо напрежение 2 × VX, програмируеми от 0.15 до 5 V
Превключваемо захранване 1 × SW12V, до 1100 mA при 20°C
Комуникационни портове 10/100 Ethernet RJ45, RS-232 и USB Micro-B
Комуникационни протоколи PakBus, Modbus, DNP3, SDI-12, TCP, UDP и други
Интернет протоколи и услуги IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, DNS, DHCP и NTP
Захранване през BAT терминали 12 V DC
Захранване през CHG терминали 16–32 V DC от захранващ преобразувател или соларен панел
Консумация в режим на покой приблизително 1.5 mA без активна Ethernet връзка
Консумация при активен процесор приблизително 36 mA; около 56 mA при активна Ethernet връзка
Точност на часовника ±1 минута на месец
Вътрешна батерия за часовника CR2032X, приблизителен живот 6 години без външно захранване
Работна температура от –40°C до +70°C, без конденз
Материал на корпуса Прахово боядисан алуминий
Размери 16.26 × 7.62 × 5.68 cm
Тегло от 288 до 306 g според комуникационната конфигурация
Програмиране CRBasic и Short Cut

Campbell Scientific CR310 – Compact Datalogger with Ethernet

The CR310 can measure a wide range of hydrological, meteorological, environmental, geotechnical, and industrial sensors. It processes and stores measurements, performs automated control functions, and makes data available through a variety of communication networks and protocols.

The main differences between the CR310 and CR300 are the integrated 10/100 Ethernet RJ45 port and the removable terminal connectors. The Ethernet interface allows direct connection to a local network, industrial router, or internet gateway without requiring a separate Ethernet communication module.

Key Benefits

  • integrated 10/100 Ethernet RJ45 port;
  • removable terminal connectors for easier wiring and maintenance;
  • USB Micro-B port for initial setup and local communication;
  • RS-232 interface for serial sensors and communication devices;
  • six analog inputs configurable as six single-ended or three differential channels;
  • 24-bit analog-to-digital converter;
  • support for SDI-12 sensors and pulse or frequency signals;
  • 0–20 mA and 4–20 mA measurements through the SE1 and SE2 inputs;
  • integrated charge regulator for a 12 V battery and solar panel;
  • integrated surge, electrostatic discharge, and power-input protection;
  • programmable using CRBasic and configurable using Short Cut;
  • suitable for autonomous and solar-powered monitoring stations.

Measurement Inputs and Control

The CR310 provides six multipurpose analog inputs that can be configured as six single-ended or three differential channels. The inputs support voltage measurements, thermocouples, thermistors, RTDs, current signals, and resistive bridge measurements.

The datalogger also provides pulse inputs, configurable digital inputs and outputs, two programmable voltage excitation terminals, and a switched 12 V output for powering sensors and communication devices.

Communication and Remote Access

The integrated Ethernet port allows the CR310 to connect directly to a local network or the internet. Supported services and protocols include HTTP and HTTPS, FTP and FTPS, email, TCP, UDP, TLS, Modbus, DNP3, PakBus, and SDI-12.

For remote installations, the CR310 can be combined with cellular or satellite communication peripherals. Versions with integrated Wi-Fi, radio, or cellular communication are also available.

Versions for Europe

  • CR310 – standard version with Ethernet, USB, and RS-232;
  • CR310-WIFI – version with integrated 2.4 GHz Wi-Fi communication;
  • CR310-RF422 – version with integrated 868 MHz radio for the European Union;
  • CR310-CELL215 – version with integrated 4G LTE CAT-1 communication for Europe, the Middle East, and Africa.
    See more for CELL215.

Applications

The Campbell Scientific CR310 is suitable for:

  • geotechnical and structural monitoring;
  • monitoring landslides, dams, bridges, and infrastructure facilities;
  • meteorological and agrometeorological stations;
  • water-resource and hydrological monitoring;
  • environmental and soil monitoring;
  • agricultural measurement systems;
  • energy and photovoltaic installations;
  • industrial measurement and automated control.

Compatibility and Programming

The CR310 is programmed using CRBasic and can be configured with Campbell Scientific Short Cut, Device Configuration Utility, PC400, or LoggerNet. It supports analog, pulse, RS-232, SDI-12, Modbus, and other serial sensors.

The CR310 does not directly support RS-485 sensors and is not compatible with SDM or CDM peripheral devices. A suitable converter is required for RS-485 communication.

Model Campbell Scientific CR310
Device type Measurement and control datalogger
Processor ARM Cortex-M4, 144 MHz
Program memory 80 MB serial flash
Data storage 30 MB serial flash
Maximum scan rate 10 Hz
Analog inputs 6 single-ended or 3 differential inputs
Analog-to-digital converter 24-bit ADC
Analog input range –100 to +2500 mV and ±34 mV range
Current measurements 0–20 mA or 4–20 mA through SE1 and SE2
Analog voltage accuracy ±(0.04% of measurement + offset) from 0°C to +40°C
Pulse counters 8
Digital inputs and outputs 7 configurable terminals
Voltage excitation terminals 2 × VX, programmable from 0.15 to 5 V
Switched power output 1 × SW12V, up to 1100 mA at 20°C
Communication ports 10/100 Ethernet RJ45, RS-232, and USB Micro-B
Communication protocols PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others
Internet protocols and services IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, DNS, DHCP, and NTP
BAT terminal power input 12 V DC
CHG terminal power input 16–32 V DC from a power converter or solar panel
Idle current consumption approximately 1.5 mA without an active Ethernet connection
Active current consumption approximately 36 mA with processor always on; approximately 56 mA with an active Ethernet link
Real-time clock accuracy ±1 minute per month
Internal clock battery CR2032X, approximately 6-year life without external power
Operating temperature –40°C to +70°C, non-condensing
Case material Powder-coated aluminum
Dimensions 16.26 × 7.62 × 5.68 cm
Weight 288 to 306 g depending on the communication option
Programming CRBasic and Short Cut