Campbell Scientific CR310
The Campbell Scientific CR310 is a multipurpose measurement, data acquisition, and control datalogger designed for small and medium-sized applications requiring reliable long-term operation, remote access, and low power consumption.
Campbell Scientific CR310 – Compact Datalogger with Ethernet
The CR310 can measure a wide range of hydrological, meteorological, environmental, geotechnical, and industrial sensors. It processes and stores measurements, performs automated control functions, and makes data available through a variety of communication networks and protocols.
The main differences between the CR310 and CR300 are the integrated 10/100 Ethernet RJ45 port and the removable terminal connectors. The Ethernet interface allows direct connection to a local network, industrial router, or internet gateway without requiring a separate Ethernet communication module.
Key Benefits
- integrated 10/100 Ethernet RJ45 port;
- removable terminal connectors for easier wiring and maintenance;
- USB Micro-B port for initial setup and local communication;
- RS-232 interface for serial sensors and communication devices;
- six analog inputs configurable as six single-ended or three differential channels;
- 24-bit analog-to-digital converter;
- support for SDI-12 sensors and pulse or frequency signals;
- 0–20 mA and 4–20 mA measurements through the SE1 and SE2 inputs;
- integrated charge regulator for a 12 V battery and solar panel;
- integrated surge, electrostatic discharge, and power-input protection;
- programmable using CRBasic and configurable using Short Cut;
- suitable for autonomous and solar-powered monitoring stations.
Measurement Inputs and Control
The CR310 provides six multipurpose analog inputs that can be configured as six single-ended or three differential channels. The inputs support voltage measurements, thermocouples, thermistors, RTDs, current signals, and resistive bridge measurements.
The datalogger also provides pulse inputs, configurable digital inputs and outputs, two programmable voltage excitation terminals, and a switched 12 V output for powering sensors and communication devices.
Communication and Remote Access
The integrated Ethernet port allows the CR310 to connect directly to a local network or the internet. Supported services and protocols include HTTP and HTTPS, FTP and FTPS, email, TCP, UDP, TLS, Modbus, DNP3, PakBus, and SDI-12.
For remote installations, the CR310 can be combined with cellular or satellite communication peripherals. Versions with integrated Wi-Fi, radio, or cellular communication are also available.
Versions for Europe
- CR310 – standard version with Ethernet, USB, and RS-232;
- CR310-WIFI – version with integrated 2.4 GHz Wi-Fi communication;
- CR310-RF422 – version with integrated 868 MHz radio for the European Union;
- CR310-CELL215 – version with integrated 4G LTE CAT-1 communication for Europe, the Middle East, and Africa.
See more for CELL215.
Applications
The Campbell Scientific CR310 is suitable for:
- geotechnical and structural monitoring;
- monitoring landslides, dams, bridges, and infrastructure facilities;
- meteorological and agrometeorological stations;
- water-resource and hydrological monitoring;
- environmental and soil monitoring;
- agricultural measurement systems;
- energy and photovoltaic installations;
- industrial measurement and automated control.
Compatibility and Programming
The CR310 is programmed using CRBasic and can be configured with Campbell Scientific Short Cut, Device Configuration Utility, PC400, or LoggerNet. It supports analog, pulse, RS-232, SDI-12, Modbus, and other serial sensors.
The CR310 does not directly support RS-485 sensors and is not compatible with SDM or CDM peripheral devices. A suitable converter is required for RS-485 communication.
| Модел | Campbell Scientific CR310 |
| Тип устройство | Дейталогер за измерване и автоматизирано управление |
| Процесор | ARM Cortex-M4, 144 MHz |
| Памет за програми | 80 MB serial flash |
| Памет за съхранение на данни | 30 MB serial flash |
| Максимална честота на сканиране | 10 Hz |
| Аналогови входове | 6 еднополюсни или 3 диференциални входа |
| Аналогово-цифров преобразувател | 24-bit ADC |
| Диапазон на аналоговите входове | от –100 до +2500 mV и диапазон ±34 mV |
| Токови сигнали | 0–20 mA или 4–20 mA чрез SE1 и SE2 |
| Точност на аналоговото измерване | ±(0.04% от измерването + offset) при 0°C до +40°C |
| Импулсни броячи | 8 |
| Цифрови входове и изходи | 7 програмируеми терминала |
| Терминали за възбуждащо напрежение | 2 × VX, програмируеми от 0.15 до 5 V |
| Превключваемо захранване | 1 × SW12V, до 1100 mA при 20°C |
| Комуникационни портове | 10/100 Ethernet RJ45, RS-232 и USB Micro-B |
| Комуникационни протоколи | PakBus, Modbus, DNP3, SDI-12, TCP, UDP и други |
| Интернет протоколи и услуги | IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, DNS, DHCP и NTP |
| Захранване през BAT терминали | 12 V DC |
| Захранване през CHG терминали | 16–32 V DC от захранващ преобразувател или соларен панел |
| Консумация в режим на покой | приблизително 1.5 mA без активна Ethernet връзка |
| Консумация при активен процесор | приблизително 36 mA; около 56 mA при активна Ethernet връзка |
| Точност на часовника | ±1 минута на месец |
| Вътрешна батерия за часовника | CR2032X, приблизителен живот 6 години без външно захранване |
| Работна температура | от –40°C до +70°C, без конденз |
| Материал на корпуса | Прахово боядисан алуминий |
| Размери | 16.26 × 7.62 × 5.68 cm |
| Тегло | от 288 до 306 g според комуникационната конфигурация |
| Програмиране | CRBasic и Short Cut |
Campbell Scientific CR310 – Compact Datalogger with Ethernet
The CR310 can measure a wide range of hydrological, meteorological, environmental, geotechnical, and industrial sensors. It processes and stores measurements, performs automated control functions, and makes data available through a variety of communication networks and protocols.
The main differences between the CR310 and CR300 are the integrated 10/100 Ethernet RJ45 port and the removable terminal connectors. The Ethernet interface allows direct connection to a local network, industrial router, or internet gateway without requiring a separate Ethernet communication module.
Key Benefits
- integrated 10/100 Ethernet RJ45 port;
- removable terminal connectors for easier wiring and maintenance;
- USB Micro-B port for initial setup and local communication;
- RS-232 interface for serial sensors and communication devices;
- six analog inputs configurable as six single-ended or three differential channels;
- 24-bit analog-to-digital converter;
- support for SDI-12 sensors and pulse or frequency signals;
- 0–20 mA and 4–20 mA measurements through the SE1 and SE2 inputs;
- integrated charge regulator for a 12 V battery and solar panel;
- integrated surge, electrostatic discharge, and power-input protection;
- programmable using CRBasic and configurable using Short Cut;
- suitable for autonomous and solar-powered monitoring stations.
Measurement Inputs and Control
The CR310 provides six multipurpose analog inputs that can be configured as six single-ended or three differential channels. The inputs support voltage measurements, thermocouples, thermistors, RTDs, current signals, and resistive bridge measurements.
The datalogger also provides pulse inputs, configurable digital inputs and outputs, two programmable voltage excitation terminals, and a switched 12 V output for powering sensors and communication devices.
Communication and Remote Access
The integrated Ethernet port allows the CR310 to connect directly to a local network or the internet. Supported services and protocols include HTTP and HTTPS, FTP and FTPS, email, TCP, UDP, TLS, Modbus, DNP3, PakBus, and SDI-12.
For remote installations, the CR310 can be combined with cellular or satellite communication peripherals. Versions with integrated Wi-Fi, radio, or cellular communication are also available.
Versions for Europe
- CR310 – standard version with Ethernet, USB, and RS-232;
- CR310-WIFI – version with integrated 2.4 GHz Wi-Fi communication;
- CR310-RF422 – version with integrated 868 MHz radio for the European Union;
- CR310-CELL215 – version with integrated 4G LTE CAT-1 communication for Europe, the Middle East, and Africa.
See more for CELL215.
Applications
The Campbell Scientific CR310 is suitable for:
- geotechnical and structural monitoring;
- monitoring landslides, dams, bridges, and infrastructure facilities;
- meteorological and agrometeorological stations;
- water-resource and hydrological monitoring;
- environmental and soil monitoring;
- agricultural measurement systems;
- energy and photovoltaic installations;
- industrial measurement and automated control.
Compatibility and Programming
The CR310 is programmed using CRBasic and can be configured with Campbell Scientific Short Cut, Device Configuration Utility, PC400, or LoggerNet. It supports analog, pulse, RS-232, SDI-12, Modbus, and other serial sensors.
The CR310 does not directly support RS-485 sensors and is not compatible with SDM or CDM peripheral devices. A suitable converter is required for RS-485 communication.
| Model | Campbell Scientific CR310 |
| Device type | Measurement and control datalogger |
| Processor | ARM Cortex-M4, 144 MHz |
| Program memory | 80 MB serial flash |
| Data storage | 30 MB serial flash |
| Maximum scan rate | 10 Hz |
| Analog inputs | 6 single-ended or 3 differential inputs |
| Analog-to-digital converter | 24-bit ADC |
| Analog input range | –100 to +2500 mV and ±34 mV range |
| Current measurements | 0–20 mA or 4–20 mA through SE1 and SE2 |
| Analog voltage accuracy | ±(0.04% of measurement + offset) from 0°C to +40°C |
| Pulse counters | 8 |
| Digital inputs and outputs | 7 configurable terminals |
| Voltage excitation terminals | 2 × VX, programmable from 0.15 to 5 V |
| Switched power output | 1 × SW12V, up to 1100 mA at 20°C |
| Communication ports | 10/100 Ethernet RJ45, RS-232, and USB Micro-B |
| Communication protocols | PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others |
| Internet protocols and services | IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, DNS, DHCP, and NTP |
| BAT terminal power input | 12 V DC |
| CHG terminal power input | 16–32 V DC from a power converter or solar panel |
| Idle current consumption | approximately 1.5 mA without an active Ethernet connection |
| Active current consumption | approximately 36 mA with processor always on; approximately 56 mA with an active Ethernet link |
| Real-time clock accuracy | ±1 minute per month |
| Internal clock battery | CR2032X, approximately 6-year life without external power |
| Operating temperature | –40°C to +70°C, non-condensing |
| Case material | Powder-coated aluminum |
| Dimensions | 16.26 × 7.62 × 5.68 cm |
| Weight | 288 to 306 g depending on the communication option |
| Programming | CRBasic and Short Cut |
Related products
-

Campbell Scientific CR1000Xe
A rugged, high-performance datalogger for multichannel measurement and control systems in demanding environments. -
Soil Instruments Vibrating Wire W9
Designed for accurate and long term measurement of pore water pressures in fully or partially saturated soil and rock. -
Soil Instruments Horizontal Digital Inclinometer System
Specially developed system for high accuracy and resolution measurement and monitoring. -
Campbel Scientific NL240
Wireless networking peripheral that provides Wi-Fi connectivity to our dataloggers and peripheral devices.