Campbell Scientific CR1000Xe
The Campbell Scientific CR1000Xe is a high-performance measurement and control datalogger. It features 16 analog inputs, a 24-bit ADC, Ethernet, USB-C, RS-232, RS-422, RS-485, CPI, CS I/O, microSD storage, and a wide 10 to 36 VDC power input range.
Campbell Scientific CR1000Xe – High-Performance Datalogger
The Campbell Scientific CR1000Xe is a high-performance measurement, data acquisition, processing, and control datalogger. Its accuracy, reliability, and rugged construction make it suitable for complex monitoring systems, multichannel measurements, and long-term operation at remote sites.
The CR1000Xe can measure analog and digital sensors, thermocouples, current-loop signals, pulse and frequency signals, SDI-12 devices, and intelligent sensors using RS-232, RS-422, or RS-485 communication. It processes and stores measurements, performs automated control functions, and transfers data through Ethernet, cellular, Wi-Fi, radio, or satellite communication systems.
The CR1000Xe replaces the CR1000X while retaining compatibility with existing CR1000X programs. The new model provides USB-C, a wide 10 to 36 VDC input range, regulated 12 V outputs, more flexible RS-232 and RS-485 communication, and enhanced Ethernet-port protection.
Key Benefits
- 16 analog inputs configurable as 16 single-ended or 8 differential channels;
- 24-bit analog-to-digital converter for high-resolution measurements;
- maximum program scan rate of 1000 Hz;
- two native inputs for direct 0–20 mA and 4–20 mA measurement;
- 10 pulse counters through P1, P2, and C1–C8;
- eight configurable digital input and output terminals;
- four programmable voltage-excitation terminals;
- USB-C for configuration and local communication;
- integrated 10/100 Ethernet port;
- support for RS-232, RS-422, RS-485, SDI-12, CS I/O, and CPI;
- microSD slot for storage expansion up to 16 GB;
- wide 10 to 36 VDC power-input range;
- regulated 12 V output and two programmable SW12V outputs;
- standard operating-temperature range from –40°C to +70°C;
- extended-temperature version from –55°C to +85°C;
- secure CampbellCloud communication using HTTPS and MQTTS;
- programmable using CRBasic and configurable with Short Cut, PC400, or LoggerNet.
Measurement Inputs and Control
The CR1000Xe provides 16 universal analog inputs that can be individually configured as 16 single-ended or 8 differential channels. They support voltage, thermocouple, RTD, thermistor, resistance-bridge, current-loop, and period-average measurements.
The dedicated RG1 and RG2 inputs allow direct measurement of current-loop signals, including 0–20 mA and 4–20 mA outputs. Four VX terminals provide programmable voltage excitation and can also supply switched, regulated 3.3 or 5 VDC power to digital sensors.
In addition to measurement, the datalogger can control relays, alarms, pumps, valves, heaters, and other external systems using its digital and switched-power outputs.
Serial Interfaces and Smart Sensors
The C1–C8 terminals can be configured for digital input and output, pulse counting, PWM, interrupts, timer measurements, and communication using RS-232, RS-422, RS-485, SDI-12, SDM, I2C, or SPI.
The CR1000Xe supports up to four independent half-duplex RS-485 connections or two full-duplex RS-422/RS-485 connections. Four independent SDI-12 terminals provide flexible connection of multiple smart sensors.
Ethernet, USB-C, and Remote Access
The integrated 10/100 Ethernet port allows direct connection to a local network, industrial router, or internet gateway. An embedded web interface provides browser-based access to system status, data, and settings.
Supported protocols and services include IPv4, IPv6, TCP, UDP, TLS, HTTP and HTTPS, FTP and FTPS, SFTP, SMTP/TLS, NTP, MQTT, SNMPv3, PakBus, Modbus, DNP3, and NMEA 0183.
The USB-C port is used for configuration, program transfer, data collection, and local computer communication. When the datalogger is powered only by USB, some power outputs and the CS I/O port are not operational.
CPI and System Expansion
The integrated CPI interface supports Campbell Scientific high-speed sensors and distributed measurement peripherals, including CDM and GRANITE modules. A CPI network can contain up to 20 devices and can cover a total cable length of up to 610 m depending on its speed and configuration.
The CR1000Xe is compatible with Campbell Scientific multiplexers, vibrating-wire interfaces, terminal input modules, and relays.
Power
The CR1000Xe can operate in nominal 12 or 24 VDC systems because of its wide 10 to 36 VDC power-input range. It provides a regulated 12 V output and two programmable SW12V outputs for powering sensors, modems, and other peripherals.
CS I/O power can be switched under program or user control, helping to reduce energy consumption in autonomous battery- and solar-powered stations.
Applications
The Campbell Scientific CR1000Xe is suitable for:
- geotechnical and structural monitoring;
- monitoring dams, mines, tunnels, bridges, and landslides;
- meteorological and hydrometeorological stations;
- water-resource and water-quality monitoring;
- air-quality and environmental monitoring;
- solar-resource assessment and photovoltaic monitoring;
- energy and industrial measurement systems;
- multichannel systems using vibrating-wire, analog, and digital sensors;
- SCADA, Modbus, and DNP3 systems;
- scientific and research applications.
Replacement for the CR1000X
The CR1000Xe is the current replacement for the CR1000X. Existing CR1000X programs can run on the CR1000Xe, simplifying the upgrade of existing monitoring systems.
Key improvements include USB-C, a 10 to 36 VDC power-input range, higher-capacity switched 12 V outputs, RS-232 and RS-485 support through all C1–C8 terminals, and enhanced Ethernet protection.
Software and Communication Options
The CR1000Xe is programmed using CRBasic and can be configured and managed with Short Cut, Device Configuration Utility, PC400, LoggerNet, CampbellGo, and CampbellCloud.
For installations without wired internet access, the datalogger can be combined with a Campbell Scientific CELL215 4G LTE cellular module.
View the other dataloggers for automated monitoring available from Solitech.
| Модел | Campbell Scientific CR1000Xe |
| Тип устройство | Високопроизводителен дейталогер за измерване и управление |
| Процесор | Renesas RX63N, 32-bit, 100 MHz, хардуерен FPU |
| Обща вградена памет | 128 MB flash и 4 MB battery-backed SRAM |
| Памет за съхранение на данни | 4 MB SRAM и 72 MB flash |
| CPU drive | 30 MB flash |
| Разширяване на паметта | Сваляема microSD карта до 16 GB |
| Период на изпълнение на програмата | От 1 ms до 1 ден |
| Максимална честота на сканиране | 1000 Hz |
| Аналогови входове | 16 еднополюсни или 8 диференциални входа |
| Аналогово-цифров преобразувател | 24-bit ADC |
| Аналогови измервателни диапазони | ±5000 mV, ±1000 mV и ±200 mV |
| Допустимо входно напрежение | ±5 V при измерване; до ±20 V без повреда |
| Точност на аналоговото измерване | ±(0.04% от измерването + offset) при 0°C до +40°C |
| Токови входове | 2 директни токови входа RG1 и RG2 за 0–20 mA и 4–20 mA |
| Максимален токов измервателен диапазон | ±80 mA |
| Импулсни броячи | 10 – P1, P2 и C1–C8 |
| Максимална импулсна честота | До 250 kHz чрез P1 и P2 |
| Цифрови входове и изходи | 8 програмируеми терминала C1–C8 |
| Терминали за възбуждащо напрежение | 4 × VX, програмируемо напрежение до ±4 V |
| Фиксиран захранващ изход | Регулиран 5 VDC и регулиран 12 VDC |
| Превключваеми 12 V изходи | 2 × SW12V плюс превключваем 12 V изход през CS I/O |
| Максимален ток на отделен 12 V/SW12 изход | До 2000 mA, в зависимост от общото натоварване и температурата |
| USB | USB Type-C 2.0, до 12 Mbps |
| Ethernet | RJ45, 10/100Base, full или half duplex, Auto-MDIX |
| RS-232 | RS-232/CPI порт и серийна комуникация чрез C1–C8 |
| RS-485 | До 4 полудуплексни или 2 пълнодуплексни връзки чрез C1–C8 |
| RS-422 | До 2 пълнодуплексни връзки чрез C1–C8 |
| SDI-12 | 4 независими SDI-12 терминала – C1, C3, C5 и C7 |
| Други комуникационни интерфейси | CS I/O, CPI, SDM, I2C и SPI |
| Комуникационни протоколи | PakBus, Modbus RTU/ASCII/TCP, DNP3, NTCIP, NMEA 0183 и други |
| Интернет протоколи и услуги | IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), SFTP, FTP(S), SMTP/TLS, MQTT(S), SNMPv3, DNS, DHCP и NTP |
| Входно захранване | 10–36 VDC |
| Консумация в режим на покой | Приблизително 2 mA при 12 VDC и под 1 mA при 24 VDC |
| Консумация при 1 Hz сканиране | Приблизително 2 mA при 12 VDC или 1.1 mA при 24 VDC |
| Консумация при 20 Hz сканиране | Приблизително 57 mA при 12 VDC или 36 mA при 24 VDC |
| Точност на часовника | ±3 минути годишно; GPS корекция до ±10 µs |
| Вътрешна батерия | 3.6 V, 2.4 Ah литиева батерия за часовника и SRAM |
| Стандартен температурен диапазон | от –40°C до +70°C |
| Разширен температурен диапазон | от –55°C до +85°C |
| Работна влажност | 0–100% RH, без конденз |
| Материал на корпуса | Алуминий с RF-екраниран вътрешен модул |
| Степен на защита | IP40 за терминалния панел; IP65 за измервателния модул при свързан панел |
| Размери | 23.8 × 10.1 × 6.2 cm |
| Тегло | 0.86 kg |
| Програмиране | CRBasic и Short Cut |
| Препоръчителна рекалибрация | На всеки 3 години |
Campbell Scientific CR1000Xe – High-Performance Datalogger
The Campbell Scientific CR1000Xe is a high-performance measurement, data acquisition, processing, and control datalogger. Its accuracy, reliability, and rugged construction make it suitable for complex monitoring systems, multichannel measurements, and long-term operation at remote sites.
The CR1000Xe can measure analog and digital sensors, thermocouples, current-loop signals, pulse and frequency signals, SDI-12 devices, and intelligent sensors using RS-232, RS-422, or RS-485 communication. It processes and stores measurements, performs automated control functions, and transfers data through Ethernet, cellular, Wi-Fi, radio, or satellite communication systems.
The CR1000Xe replaces the CR1000X while retaining compatibility with existing CR1000X programs. The new model provides USB-C, a wide 10 to 36 VDC input range, regulated 12 V outputs, more flexible RS-232 and RS-485 communication, and enhanced Ethernet-port protection.
Key Benefits
- 16 analog inputs configurable as 16 single-ended or 8 differential channels;
- 24-bit analog-to-digital converter for high-resolution measurements;
- maximum program scan rate of 1000 Hz;
- two native inputs for direct 0–20 mA and 4–20 mA measurement;
- 10 pulse counters through P1, P2, and C1–C8;
- eight configurable digital input and output terminals;
- four programmable voltage-excitation terminals;
- USB-C for configuration and local communication;
- integrated 10/100 Ethernet port;
- support for RS-232, RS-422, RS-485, SDI-12, CS I/O, and CPI;
- microSD slot for storage expansion up to 16 GB;
- wide 10 to 36 VDC power-input range;
- regulated 12 V output and two programmable SW12V outputs;
- standard operating-temperature range from –40°C to +70°C;
- extended-temperature version from –55°C to +85°C;
- secure CampbellCloud communication using HTTPS and MQTTS;
- programmable using CRBasic and configurable with Short Cut, PC400, or LoggerNet.
Measurement Inputs and Control
The CR1000Xe provides 16 universal analog inputs that can be individually configured as 16 single-ended or 8 differential channels. They support voltage, thermocouple, RTD, thermistor, resistance-bridge, current-loop, and period-average measurements.
The dedicated RG1 and RG2 inputs allow direct measurement of current-loop signals, including 0–20 mA and 4–20 mA outputs. Four VX terminals provide programmable voltage excitation and can also supply switched, regulated 3.3 or 5 VDC power to digital sensors.
In addition to measurement, the datalogger can control relays, alarms, pumps, valves, heaters, and other external systems using its digital and switched-power outputs.
Serial Interfaces and Smart Sensors
The C1–C8 terminals can be configured for digital input and output, pulse counting, PWM, interrupts, timer measurements, and communication using RS-232, RS-422, RS-485, SDI-12, SDM, I2C, or SPI.
The CR1000Xe supports up to four independent half-duplex RS-485 connections or two full-duplex RS-422/RS-485 connections. Four independent SDI-12 terminals provide flexible connection of multiple smart sensors.
Ethernet, USB-C, and Remote Access
The integrated 10/100 Ethernet port allows direct connection to a local network, industrial router, or internet gateway. An embedded web interface provides browser-based access to system status, data, and settings.
Supported protocols and services include IPv4, IPv6, TCP, UDP, TLS, HTTP and HTTPS, FTP and FTPS, SFTP, SMTP/TLS, NTP, MQTT, SNMPv3, PakBus, Modbus, DNP3, and NMEA 0183.
The USB-C port is used for configuration, program transfer, data collection, and local computer communication. When the datalogger is powered only by USB, some power outputs and the CS I/O port are not operational.
CPI and System Expansion
The integrated CPI interface supports Campbell Scientific high-speed sensors and distributed measurement peripherals, including CDM and GRANITE modules. A CPI network can contain up to 20 devices and can cover a total cable length of up to 610 m depending on its speed and configuration.
The CR1000Xe is compatible with Campbell Scientific multiplexers, vibrating-wire interfaces, terminal input modules, and relays.
Power
The CR1000Xe can operate in nominal 12 or 24 VDC systems because of its wide 10 to 36 VDC power-input range. It provides a regulated 12 V output and two programmable SW12V outputs for powering sensors, modems, and other peripherals.
CS I/O power can be switched under program or user control, helping to reduce energy consumption in autonomous battery- and solar-powered stations.
Applications
The Campbell Scientific CR1000Xe is suitable for:
- geotechnical and structural monitoring;
- monitoring dams, mines, tunnels, bridges, and landslides;
- meteorological and hydrometeorological stations;
- water-resource and water-quality monitoring;
- air-quality and environmental monitoring;
- solar-resource assessment and photovoltaic monitoring;
- energy and industrial measurement systems;
- multichannel systems using vibrating-wire, analog, and digital sensors;
- SCADA, Modbus, and DNP3 systems;
- scientific and research applications.
Replacement for the CR1000X
The CR1000Xe is the current replacement for the CR1000X. Existing CR1000X programs can run on the CR1000Xe, simplifying the upgrade of existing monitoring systems.
Key improvements include USB-C, a 10 to 36 VDC power-input range, higher-capacity switched 12 V outputs, RS-232 and RS-485 support through all C1–C8 terminals, and enhanced Ethernet protection.
Software and Communication Options
The CR1000Xe is programmed using CRBasic and can be configured and managed with Short Cut, Device Configuration Utility, PC400, LoggerNet, CampbellGo, and CampbellCloud.
For installations without wired internet access, the datalogger can be combined with a Campbell Scientific CELL215 4G LTE cellular module.
View the other dataloggers for automated monitoring available from Solitech.
| Model | Campbell Scientific CR1000Xe |
| Device type | High-performance measurement and control datalogger |
| Processor | Renesas RX63N, 32-bit, 100 MHz, hardware FPU |
| Total onboard memory | 128 MB flash and 4 MB battery-backed SRAM |
| Data storage | 4 MB SRAM and 72 MB flash |
| CPU drive | 30 MB flash |
| Storage expansion | Removable microSD card up to 16 GB |
| Program execution period | 1 ms to 1 day |
| Maximum scan rate | 1000 Hz |
| Analog inputs | 16 single-ended or 8 differential inputs |
| Analog-to-digital converter | 24-bit ADC |
| Analog measurement ranges | ±5000 mV, ±1000 mV, and ±200 mV |
| Input limits | ±5 V measurement input; ±20 V without damage |
| Analog voltage accuracy | ±(0.04% of measurement + offset) from 0°C to +40°C |
| Current inputs | 2 native RG1 and RG2 inputs for 0–20 mA and 4–20 mA signals |
| Maximum current measurement range | ±80 mA |
| Pulse counters | 10 – P1, P2, and C1–C8 |
| Maximum pulse frequency | Up to 250 kHz through P1 and P2 |
| Digital inputs and outputs | 8 configurable C1–C8 terminals |
| Voltage excitation terminals | 4 × VX, programmable excitation up to ±4 V |
| Fixed power outputs | Regulated 5 VDC and regulated 12 VDC |
| Switched 12 V outputs | 2 × SW12V plus switched 12 V through CS I/O |
| Maximum individual 12 V/SW12 output | Up to 2000 mA, subject to total system load and temperature |
| USB | USB Type-C 2.0, up to 12 Mbps |
| Ethernet | RJ45, 10/100Base, full or half duplex, Auto-MDIX |
| RS-232 | RS-232/CPI port and serial communication through C1–C8 |
| RS-485 | Up to 4 half-duplex or 2 full-duplex connections through C1–C8 |
| RS-422 | Up to 2 full-duplex connections through C1–C8 |
| SDI-12 | 4 independent SDI-12 terminals – C1, C3, C5, and C7 |
| Additional communication interfaces | CS I/O, CPI, SDM, I2C, and SPI |
| Communication protocols | PakBus, Modbus RTU/ASCII/TCP, DNP3, NTCIP, NMEA 0183, and others |
| Internet protocols and services | IPv4, IPv6, TCP, UDP, TLS 1.2, HTTP(S), SFTP, FTP(S), SMTP/TLS, MQTT(S), SNMPv3, DNS, DHCP, and NTP |
| Power input | 10–36 VDC |
| Idle current consumption | Approximately 2 mA at 12 VDC and less than 1 mA at 24 VDC |
| Current consumption at 1 Hz scan | Approximately 2 mA at 12 VDC or 1.1 mA at 24 VDC |
| Current consumption at 20 Hz scan | Approximately 57 mA at 12 VDC or 36 mA at 24 VDC |
| Real-time clock accuracy | ±3 minutes per year; optional GPS correction to ±10 µs |
| Internal battery | 3.6 V, 2.4 Ah lithium battery for clock and SRAM backup |
| Standard operating-temperature range | –40°C to +70°C |
| Extended operating-temperature range | –55°C to +85°C |
| Operating humidity | 0–100% RH, non-condensing |
| Case material | Aluminum with an RF-shielded internal module |
| Ingress protection | IP40 wiring panel; IP65 measurement module when connected to the panel |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Programming | CRBasic and Short Cut |
| Recommended recalibration | Every 3 years |
Campbell Scientific CR1000Xe Product Brochure
CR1000Xe Detailed Specifications
CR1000X and CR1000Xe Product Comparison
CR1000X/CR1000Xe Getting Started Guide
CR1000X/CR1000Xe Online Product Manual
CR1000X/CR1000Xe Product Manual PDF
Campbell Scientific CR1000Xe EU Declaration of Conformity
Documents open on the official Campbell Scientific website.
Related products
-
Soil Instruments Horizontal Digital Inclinometer System
Specially developed system for high accuracy and resolution measurement and monitoring. -
Soil Instruments VWlog2
Simple, rugged, low-power, 2 channel Datalogger -
Campbell Scientific CS451
Pressure transducer with a a stainless-steel case. -
Soil Instruments Vibrating Wire Temperature Sensor
Establish a temperature relationship between structural changes and measurement result.


