Campbell Scientific ClariVue 20 – Turbidity Sensor

The Campbell Scientific ClariVue 20 is a submersible titanium turbidity sensor with a measurement range of up to 4000 FNU. It supports SDI-12, Modbus RS-485, and analog communication for freshwater, saline, and industrial-water monitoring.



Campbell Scientific ClariVue 20 – Submersible Turbidity Sensor

The Campbell Scientific ClariVue 20 is a submersible optical sensor for measuring turbidity in water with low or high concentrations of suspended particles. It complies with ISO 7027-1:2016 and uses 90-degree side-scatter optical measurement.

Its titanium housing and sapphire optical window make it suitable for freshwater, saline, and highly corrosive environments. The sensor can operate at depths of up to 500 m.

Key Benefits

  • measurement range from 0 to 4000 FNU;
  • ISO 7027-1:2016 compliance;
  • 90-degree side-scatter measurement;
  • SDI-12 version 1.4 communication;
  • Modbus communication through RS-485;
  • 0 to 1 VDC analog output;
  • rugged titanium housing;
  • sapphire optical window;
  • maximum deployment depth of 500 m;
  • suitable for freshwater and saline environments;
  • integrated internal-temperature measurement;
  • wet-mateable underwater connector.

Measurement Principle

The ClariVue 20 emits light into the water and measures the energy scattered at 90 degrees by suspended particles. Turbidity may be used as a surrogate for suspended-sediment concentration after a site-specific relationship has been established using laboratory samples.

Communication

The sensor supports SDI-12, Modbus through RS-485, and a 0 to 1 VDC analog output. It can therefore be integrated with Campbell Scientific dataloggers and compatible third-party controllers.

Applications

  • river, lake, and reservoir monitoring;
  • coastal and marine-water monitoring;
  • suspended-sediment monitoring;
  • construction, dredging, and mining operations;
  • surface-water quality monitoring;
  • wastewater and industrial-effluent monitoring;
  • erosion and sediment-transport studies.

Maintenance

The optical surface should be inspected and cleaned periodically, especially at sites with strong biological growth. The sensor must not be allowed to freeze while encased in water, as expanding ice may damage the housing.

View the other dataloggers for automated monitoring available from Solitech.

Модел Campbell Scientific ClariVue 20
Тип устройство Потопяем оптичен сензор за мътност
Метод на измерване 90° странично разсейване
Стандарт ISO 7027-1:2016
Измервателен диапазон 0 до 4000 FNU
Резолюция 0.2 FNU
Точност ±2% или 0.5 FNU, която стойност е по-голяма
Размер на измерваните частици 0.1 до 0.5 µm
Комуникационни интерфейси SDI-12 v1.4, Modbus чрез RS-485 и аналогов изход
Аналогов изход 0 до 1 VDC
SDI-12 време за измерване 12 до 28 s според използваната команда
Вътрешно измерване на температурата Точност ±0.2°C
Захранване 9.6 до 18 VDC
Консумация при включване 71 mA за приблизително 5 s
Консумация в покой 0.75 mA
Консумация при измерване 32 mA
Работна температура От –2°C до +40°C
Максимална дълбочина 500 m
Материал на корпуса Титан
Материал на челната част Титан
Оптика Сапфирена леща
Конектор Титаниев wet-mateable конектор със златно покрити контакти
Кабел Шестпроводен кабел с полиуретанова обвивка и водна блокировка
Уплътнение на оптиката Двойни O-пръстени
Диаметър 3.0 cm
Дължина 16.6 cm
Тегло Приблизително 200 g

Campbell Scientific ClariVue 20 – Submersible Turbidity Sensor

The Campbell Scientific ClariVue 20 is a submersible optical sensor for measuring turbidity in water with low or high concentrations of suspended particles. It complies with ISO 7027-1:2016 and uses 90-degree side-scatter optical measurement.

Its titanium housing and sapphire optical window make it suitable for freshwater, saline, and highly corrosive environments. The sensor can operate at depths of up to 500 m.

Key Benefits

  • measurement range from 0 to 4000 FNU;
  • ISO 7027-1:2016 compliance;
  • 90-degree side-scatter measurement;
  • SDI-12 version 1.4 communication;
  • Modbus communication through RS-485;
  • 0 to 1 VDC analog output;
  • rugged titanium housing;
  • sapphire optical window;
  • maximum deployment depth of 500 m;
  • suitable for freshwater and saline environments;
  • integrated internal-temperature measurement;
  • wet-mateable underwater connector.

Measurement Principle

The ClariVue 20 emits light into the water and measures the energy scattered at 90 degrees by suspended particles. Turbidity may be used as a surrogate for suspended-sediment concentration after a site-specific relationship has been established using laboratory samples.

Communication

The sensor supports SDI-12, Modbus through RS-485, and a 0 to 1 VDC analog output. It can therefore be integrated with Campbell Scientific dataloggers and compatible third-party controllers.

Applications

  • river, lake, and reservoir monitoring;
  • coastal and marine-water monitoring;
  • suspended-sediment monitoring;
  • construction, dredging, and mining operations;
  • surface-water quality monitoring;
  • wastewater and industrial-effluent monitoring;
  • erosion and sediment-transport studies.

Maintenance

The optical surface should be inspected and cleaned periodically, especially at sites with strong biological growth. The sensor must not be allowed to freeze while encased in water, as expanding ice may damage the housing.

View the other dataloggers for automated monitoring available from Solitech.

Model Campbell Scientific ClariVue 20
Device type Submersible side-scatter turbidity sensor
Measurement method 90-degree optical side-scatter measurement
Measurement standard ISO 7027-1:2016 compliant
Measurement range 0 to 4000 FNU
Resolution 0.2 FNU
Accuracy ±2% of reading or ±0.5 FNU, whichever is greater
Particle-size specification 0.1 to 0.5 µm
Signal types SDI-12 v1.4, Modbus over RS-485, and analog
Analog output 0 to 1 VDC
SDI-12 measurement response time 12 to 28 seconds, depending on the SDI-12 command
Internal temperature measurement ±0.2°C accuracy
Power requirements 9.6 to 18 VDC
Initial measurement consumption 32 mA for approximately 30 seconds
Idle current consumption 0.75 mA
Measurement current consumption 32 mA
Operating temperature –2°C to +40°C
Maximum deployment depth 500 m
Housing material Titanium
Sensor-head material Titanium
Optical window Sapphire lens
Connector MCBH-5-FS titanium wet-mateable connector with gold-plated contacts
Cable type Six-conductor cable with polyurethane jacket and water block
Optical assembly sealing Double O-ring seals
Sensor diameter 3.0 cm
Sensor length 16.6 cm